Understanding Explosion Proof Lighting Classes, Divisions, and Groups

 

Navigating the complexities of explosion proof light ratings requires careful attention to detail. Given the diverse nature of hazardous workplace environments, a detailed classification system becomes essential to maintain workplace safety standards. The market offers an extensive range of explosion proof equipment, encompassing explosion proof light towers, explosion proof string lights, explosion proof exit signs, and numerous other hazardous area lighting solutions. A thorough understanding of these lighting classifications is crucial for selecting the appropriate lighting solution for specific workplace requirements.

Definition and Construction of Explosion Proof Lighting

 

It’s essential to address a common misconception regarding explosion proof lighting – specifically, the term “explosion proof” itself. Contrary to what the name might suggest, an explosion proof rated light fixture isn’t designed to withstand an explosion. Rather, its primary function is to prevent the fixture from initiating an external explosion.

To illustrate this, consider a Class I Division 1 fixture. These units are engineered to contain any internal explosion within the fixture should their components initiate one. The fixture’s design ensures that neither external heat from the surrounding environment nor any internal electrical arcs or sparks can trigger an ignition. As we delve deeper into the classification system, the varying explosion proof characteristics of different equipment categories become more apparent.

Class I Division 2 lighting operates under less stringent requirements compared to Division 1 products. While Division 2 fixtures aren’t required to contain an explosion, they must demonstrate an inability to cause explosions in their approved operating environments. These environments are categorized into various groups representing different hazardous work locations. In this context, an intrinsically safe light refers to a fixture that’s incapable of causing any form of explosion.

Multiple design approaches can achieve this safety standard, but the most prevalent method involves the fixture’s ability to contain ignited flammable vapors or gases internally. These gases are retained until they cool sufficiently to prevent any risk of igniting vapors in the workplace atmosphere upon their eventual release. The specific mechanisms for ensuring the safe release of cooled gases from explosion proof equipment can vary significantly based on each item’s design and classification requirements.

With a clear understanding of explosion proof terminology, it becomes evident that explosion proof lighting isn’t a universal solution for all hazardous work environments. In fact, an explosion proof light that provides safe operation in one setting could pose significant risks in another. This underscores the importance of thoroughly understanding the classification system and the various work environments it encompasses.

Understanding Class and Division

The explosion proof lighting classification system comprises three primary categories: Class I, Class II, and Class III. These classifications represent the fundamental distinctions between different types of explosion proof lighting solutions. Each class is further subdivided into two distinct divisions to provide more specific guidance for different operational scenarios.

Here’s a comprehensive breakdown of these classes and their respective divisions:

  • Class I, Division 1 – Environments where ignitable concentrations of flammable gases, vapors, or liquids are consistently or frequently present in the atmosphere during normal operational conditions.
  • Class I, Division 2 – Settings where ignitable concentrations of flammable gases, vapors, or liquids may be present in the atmosphere under irregular or abnormal operating conditions.
  • Class II, Division 1 – Locations where ignitable concentrations of combustible dust particles are present in the atmosphere during standard operating conditions.
  • Class II, Division 2 – Areas where ignitable concentrations of combustible dust may be present in the atmosphere under non-standard or abnormal operating conditions.
  • Class III, Division 1 – Environments where easily ignitable fibers or materials that produce combustible flyings are present in the atmosphere during regular operational conditions.
  • Class III, Division 2 – Locations where easily ignitable fibers or materials that produce combustible flyings may be present in the atmosphere under irregular operating conditions.

Class III environments typically include facilities such as textile mills, cotton gins, cotton-seed processing plants, flax-processing facilities, clothing manufacturing operations, woodworking facilities, and other industrial settings where combustible fibers and flyings are integral to the manufacturing process.

Common materials found in Class III environments include: rayon, cotton (including cotton linters and waste), sisal, henequen, istle, jute, hemp, Spanish moss, excelsior, tow, cocoa fiber, oakum, and baled waste kapok.

Important: These classifications are specific to the United States and were established by the National Fire Protection Association’s National Electric Code, with some degree of compatibility with Canadian standards.

Breaking Down The Groups

While the class and division system provides a robust framework for ensuring appropriate lighting installation across various work environments, a more detailed categorization becomes necessary due to the diverse range of flammable materials present across different industries.

To address this complexity, the classification system incorporates groups. Below are the different groups and their class associations:

Class I Groups

  • Group A: Acetylene
  • Group B: Hydrogen
  • Group B Exceptions:
    • Exception 1) Group D equipment may be utilized in Group B atmospheres containing butadiene, provided explosion-proof seals are installed within 18 inches of the enclosure in all conduit runs into explosion-proof equipment.
    • Exception 2) Group C equipment may be employed in Group B atmospheres containing allyl glycidyl ether, n-butyl glycidyl ether, ethylene oxide, propylene oxide, and acrolein, subject to the same requirements outlined in Exception 1.
  • Group C: Propane and Ethylene.

Group D: Benzene, Butane, Methane & Propane

Group D Note: Ammonia-based atmospheres follow a distinct area classification system and cannot be fully categorized within Group D or other groups discussed in this article. For detailed guidelines, consult ANSI/ASHRAE 15-1994, Safety Code for Mechanical Information and ANSI/CGA G2.1-1989, Safety Requirements for the Storage and Handling of Anhydrous Ammonia.

Class I Group Exception: Carbon disulfide necessitates enhanced safety measures beyond standard Class I group requirements, owing to its exceptionally low autoignition temperature and specific joint clearance requirements for flame containment.

Class II Groups

  • Group E: Metal Dust – Encompasses aluminum, magnesium, their commercial alloy variants, and similar combustible dusts that pose comparable hazards when exposed to electrical equipment.
    Group E Note: This classification excludes certain metal dusts. Specifically, zirconium, thorium, and uranium dusts exhibit significantly lower ignition temperatures and minimum ignition energies than materials in Class I or Class II, necessitating additional safety protocols.
  • Group F: Carbon and Charcoal – Encompasses materials such as coal dust, carbon black particles, charcoal residue, and coke dust.
  • Group G: Encompasses combustible dusts not classified under Group E or Group F, including flour, grain, wood, plastic, and chemical dusts. Certain materials may require supplementary safety measures.

Class III Groups

Class III utilizes a simplified structure with no group subdivisions, featuring only Division 1 and Division 2 classifications for fibers and flyings.

Worksite Lighting LLC offers an extensive selection of explosion proof lighting solutions, including:

At Worksite Lighting, our expertise extends beyond lighting solutions. We specialize in providing replacement components, retrofit solutions, and upgrade parts, alongside industrial-grade power accessories. Our skilled technicians excel in custom-building lighting systems and accessories that precisely align with your operational requirements. Since 2008, our unwavering dedication to honesty, quality, and reliability has established us as an industry leader in lighting and electronics. For detailed information about our customized solutions designed for your specific industry requirements, contact us at 877-861-5255 or reach out via sales@worksitelighting.com

 